Buku Manual Mesin Absensi Amano Ex3500n



CONDENSER DESIGN Condensation on horizontal tubes (Nusselt theory) Heat transfer coefficient is obtained by h=0.728[kL3 ϸL(ϸL- ϸV)g ƛ /µL (Tv –TW) D] Where kL – thermal conductivity of liquid ϸL – density of liquid ϸV –density of vapour ƛ – latent heat of condensation of steam g- Gravitational acceleration =9.81m/s2 µL – viscosity of liquid TW – temperature of surface Tv –temperature of vapour D –diameter The above eqn applies for a single tube or single row of tubes. When tubes are stacked over each other the heat coefficient is calculated as H=h NR-1/6 Nr- no of rows of horizontal tubes
As the properties(kL, ϸL, µL) of the condensate changes with the temperature ,so some modifications are being done to compensate for that . Tf =βTw +(1- β)Tsat Where β-weight factor (recommended in the literature from 0.5 to 0.75) Condensate sub cooling The temp in the condensate film drops from Tsat at the liquid vapour interface to Tw at the wall. Therefore the avg condensate temperature, TL is less than Tsat, and hence the condensate leaving the surface is sub cooled. Accounting for sub cooling, the rate of heat transfer is Q=W ƛ +WCp,L (Tsat - TL)= Whfg*
Cp,L heat capacity of condensate W- condensation rate to account for both sub cooling and inertial effects h/hNu =(1+(0.683 -0.228 PrL-1)Ԑ)^0.25 hNu - heat transfer coeff by basic nusselt theory Ԑ- Cp,L (Tsat - Tw)/ƛ PrL - Cp,L µL/ kL above eqn is valid for Pr>0.6 Q=NhD0L∏(Tsat - Tw) Tw=…………… Then Tf can be obtained by the eqn given above Mass flow rate of water =ϸAu U –flow velocity A of tube can be calculated from the above eqn And the total area= N∏DL And the condensation rate –Q/hfg* Some FACTS to remember 

In drop wise condensation Heat transfer coefficient is considerably high as compared to film condensation. The reason being the direct contact of vapor with the cooler surface. The effectiveness of a condenser can be calculated as (1 - eNTU) NTU=(UA/Cmin) Cmin=(mCp)min
References –process heat transfer principles and applications by ROBERT W SERTH Heat and mass transfer –cengel and ghajar

Buku Manual Mesin Absensi Amano Ex3500n Time Clock

Harga mesin absensi amano

PROCESS DESIGN OF SHELL AND TUBE HEAT EXCHANGER, CONDENSER AND REBOILERS. Calculation of heat transfer co-efficient. Type of heat exchanger and design pressure. Downloads lagu opick taubat. The optimum thermal design of a shell and tube heat exchanger involves the. Tube heat exchangers calculations it is very important to remember some. Sandhya namam lyrics in malayalam pdf software. Tower Design Free Online eBook Collection at: www.pdftop.com/ebook/tower+design. Thermal design calculations of Shell & Tube condensers for horizontal condensers, vertical condensers including reflux condensers; main features: +Support S.I.

  1. Jual AMANO EX-3500N - Mesin Absensi Kartu dengan harga Rp1.590.000 dari toko online Online Kios, Jakarta Barat. Cari produk Mesin Absensi lainnya di Tokopedia.
  2. Harga: Kartu absensi untuk mesin absen amano dan sejenisnya merk jerukRp14.500: Harga: Amano Inked Ribbon Cartridge (Pita Mesin Absen) EX6000/EX3500 ORIGINALRp85.000: Harga: Mesin Absen Manual Amano EX 3500 NRp1.600.000: Harga: Pita / Tinta Mesin Absen Amano EX3500N / BX6200 /.
  3. Mesin absensi Amano EX3500N memberikan kepastian dan kenyamanan dalam setting dan konfigurasi jam kerja. Didesain dengan struktur dan bahan yang kokoh, mesin absensi Amano EX3500 merupakan mesin absen yang sempat menjadi primadona di industri mesin absensi selama bertahun-tahun, sebelum teknologi sidik jari berhasil dikembangkan.
Buku Manual Mesin Absensi Amano Ex3500n

Amano

View and Download Amano EX3500N operation manual online. Electronic time recorder. EX3500N clock pdf manual download. View and Download Amano EX-3500 user manual online. EX-3500 Clock pdf manual download. Description Mesin Absensi AMANO EX3500N AMANO ELECTRONIC TIME RECORDER EX3500N (Mesin Absensi AMANO EX3500N) merupakan Mesin Absensi yang paling banyak digunakan oleh perusahaan perusahaan di dunia.





Comments are closed.